Slot Number Invalid Bdo

2021年4月18日
Register here: http://gg.gg/p31fo
*Slot Number Invalid Bdo Account
*Slot Number Invalid Bdo Contact
Whilst the green number is the amount you have earned whilst under your current contract. The green number will reset every time you take a new contract. Each time you earn 100 activity points, you are able to earn a 1% raise for your next contract renewal (max 100% / 10,000 activity points). 14 is currently the max. You can pick up one character slot for free right now - its in pearl shop - loyalty tab. You can get character slots for loyalty and pearl shop aswell. I am not sure what is the starting amount - used to be around 4 I think.Slot Number Invalid Bdo Account2013-09-16 00:07:21 UTCSlot Number Invalid Bdo Contact Hello.I have an LSI 9211-8i controller which is running the IR firmware. Myintention is to flash it with the IT firmware and use it for an mdRAID array.However I don’t think it is playing nicely with my motherboard BIOS.On first installing it, with no drives attached, the LSI BIOS runs andthen the motherboard BIOS goes through an AHCI drive detection phase.After detecting the drives (2xHD 1xOptical, connected to SATA ports onMB) the boot hung and required a hard reset.The LSI MPT2BIOS version is 7.29.0.0 and the controller firmware is 15.0.0.0-IR.The motherboard is a Gigabyte GA-MA78G-DS3H (revision 1) running the F3 BIOS.I can enter the LSI configuration utility during the controller bootprocess and I see that it has a PCI slot of ’ff’ which, according tothe utility, indicates an invalid PCI slot.I’ve updated to the latest motherboard BIOS (F9) and now the bootprocess follows the same sequence but continues after the AHCIdetection and eventually brings up linux. However the controllerstill reports a PCI slot of ’ff’.I can see it in linux but if I have a drive connected I don’t see itin the boot configuration utility (not sure if I should) and I don’tsee it as a /dev/sd? device (not sure if this is where I should findit). So I suspect it’s not really working.Here is the output from lspci -v:02:00.0 Serial Attached SCSI controller: LSI Logic / Symbios LogicSAS2008 PCI-Express Fusion-MPT SAS-2 [Falcon] (rev 03)Subsystem: LSI Logic / Symbios Logic Device 3020Flags: bus master, fast devsel, latency 0, IRQ 18I/O ports at de00 [size=256]Memory at fdcfc000 (64-bit, non-prefetchable) [size=16K]Memory at fdc80000 (64-bit, non-prefetchable) [size=256K][virtual] Expansion ROM at fdb00000 [disabled] [size=512K]Capabilities: [50] Power Management version 3Capabilities: [68] Express Endpoint, MSI 00Capabilities: [d0] Vital Product DataCapabilities: [a8] MSI: Enable- Count=1/1 Maskable- 64bit+Capabilities: [c0] MSI-X: Enable+ Count=15 Masked-Capabilities: [100] Advanced Error ReportingCapabilities: [138] Power Budgeting <?>Capabilities: [150] Single Root I/O Virtualization (SR-IOV)Capabilities: [190] Alternative Routing-ID Interpretation (ARI)Kernel driver in use: mpt2sasKernel modules: mpt2sasAnybody run into this or have any advice? Is this really a problem?I’m reluctant to risk bricking it during a firmware flash if it trulyis misbehaving.Thanks.--To unsubscribe from this list: send the line ’unsubscribe linux-raid’ inthe body of a message to ***@vger.kernel.orgMore majordomo info at http://vger.kernel.org/majordomo-info.html
Register here: http://gg.gg/p31fo

https://diarynote.indered.space

コメント

最新の日記 一覧

<<  2025年6月  >>
1234567
891011121314
15161718192021
22232425262728
293012345

お気に入り日記の更新

テーマ別日記一覧

まだテーマがありません

この日記について

日記内を検索